有时候新接手维护服务器,或者在考虑当前服务器容灾备份机制时,首先得知道服务器到底是否存在RAID卡,是否已经配置RAID。最简单的方式就是重启服务器,然后根据提示查看相关信息。但很多情况下不能随便重启机器,那么我们可以通过特定的操作系统命令,或者查看相关日志得到该信息。注:此处讨论的是硬件RAID,不包括软件RAID
# lspci | grep RAID
02:00.0 RAID bus controller: Hewlett-Packard Company Smart Array Gen8 Controllers (rev 01)
该命令查看了当前服务器是否存在RAID控制器,如果输出类似上面的信息,则表示硬件支持RAID,但实际是否配置以及如何配置还得进一步确定。
# dmesg |grep -i raid
dracut: rd_NO_DM: removing DM RAID activation
dracut: rd_NO_MD: removing MD RAID activation
hpsa 0000:02:00.0: RAID device c2b3t0l0 added.
scsi 2:3:0:0: RAID HP P420i 3.42 PQ: 0 ANSI: 5
如上所示,在系统日志中可以看到存在RAID设备,以及设备型号等信息。或者通过以下命令查看:
# cat /proc/scsi/scsi
Attached devices:
Host: scsi1 Channel: 00 Id: 00 Lun: 00
Vendor: hp Model: DVDRAM GT80N Rev: EA02
Type: CD-ROM ANSI SCSI revision: 05
Host: scsi2 Channel: 03 Id: 00 Lun: 00
Vendor: HP Model: P420i Rev: 3.42
Type: RAID ANSI SCSI revision: 05
Host: scsi2 Channel: 00 Id: 00 Lun: 00
Vendor: HP Model: LOGICAL VOLUME Rev: 3.42
Type: Direct-Access ANSI SCSI revision: 05
Host: scsi2 Channel: 00 Id: 00 Lun: 01
Vendor: HP Model: LOGICAL VOLUME Rev: 3.42
Type: Direct-Access ANSI SCSI revision: 05
该命令显示了当前系统做完RAID后的磁盘个数,其中第二项显示为RAID磁盘,但没有显示RAID级别。
该部分内容通常无法通过系统自带命令或日志进行查询,需要使用RAID设备厂商提供的专用软件查看,此处以HP(惠普)服务器为例,进行演示。
下载工具
可通过官方网站下载工具 hpacucli-9.40-12.0.x86_64.rpm 点击此处
安装工具
# rpm -ivh hpacucli-9.40-12.0.x86_64.rpm
工具使用
# hpacucli ctrl all show config
Smart Array P420i in Slot 0 (Embedded) (sn: 50014380263D1E40)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (279.4 GB, RAID 1, OK)
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SAS, 300 GB, OK)
physicaldrive 2I:2:5 (port 2I:box 2:bay 5, SAS, 300 GB, OK)
array B (SAS, Unused Space: 0 MB)
logicaldrive 2 (1.1 TB, RAID 0, OK)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SAS, 300 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SAS, 300 GB, OK)
physicaldrive 2I:2:6 (port 2I:box 2:bay 6, SAS, 300 GB, OK)
physicaldrive 2I:2:7 (port 2I:box 2:bay 7, SAS, 300 GB, OK)
SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380 (WWID: 50014380263D1E4F)
# hpacucli ctrl all show config detail
Smart Array P420i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 50014380263D1E40
Cache Serial Number: PBKUC0BRH4J3G6
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 3.42
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 10% Read / 90% Write
Drive Write Cache: Disabled
Total Cache Size: 1024 MB
Total Cache Memory Available: 816 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Spare Activation Mode: Activate on drive failure
Controller Temperature (C): 68
Cache Module Temperature (C): 36
Capacitor Temperature (C): 28
Array: A
Interface Type: SAS
Unused Space: 0 MB
Status: OK
Array Type: Data
Logical Drive: 1
Size: 279.4 GB
Fault Tolerance: 1
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 256 KB
Status: OK
Caching: Enabled
Unique Identifier: 600508B1001C66AE8BFFC07021D139D8
Disk Name: /dev/sda
Mount Points: /boot 200 MB, / 279.2 GB
OS Status: LOCKED
Logical Drive Label: A84609D850014380263D1E4034C5
Mirror Group 0:
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SAS, 300 GB, OK)
Mirror Group 1:
physicaldrive 2I:2:5 (port 2I:box 2:bay 5, SAS, 300 GB, OK)
Drive Type: Data
Caching Association: None
physicaldrive 1I:2:1
Port: 1I
Box: 2
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD6
Serial Number: EB01PD21MUW01306
Model: HP EG0300FBDSP
Current Temperature (C): 35
Maximum Temperature (C): 42
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 2I:2:5
Port: 2I
Box: 2
Bay: 5
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD6
Serial Number: EB01PCC1L8861251
Model: HP EG0300FBDSP
Current Temperature (C): 34
Maximum Temperature (C): 41
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
Array: B
Interface Type: SAS
Unused Space: 0 MB
Status: OK
Array Type: Data
Logical Drive: 2
Size: 1.1 TB
Fault Tolerance: 0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 256 KB
Status: OK
Caching: Enabled
Unique Identifier: 600508B1001CD6F301652A600B3E372A
Disk Name: /dev/sdb
Mount Points: /mnt/u01 1.1 TB
OS Status: LOCKED
Logical Drive Label: A846B29850014380263D1E403EF7
Drive Type: Data
Caching Association: None
physicaldrive 1I:2:2
Port: 1I
Box: 2
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD1
Serial Number: ECA1PAC00GH11050
Model: HP EG0300FBDSP
Current Temperature (C): 34
Maximum Temperature (C): 44
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 1I:2:3
Port: 1I
Box: 2
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD6
Serial Number: EB01PD21MUYN1306
Model: HP EG0300FBDSP
Current Temperature (C): 33
Maximum Temperature (C): 45
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 2I:2:6
Port: 2I
Box: 2
Bay: 6
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD6
Serial Number: EB01PD21MVFN1306
Model: HP EG0300FBDSP
Current Temperature (C): 32
Maximum Temperature (C): 43
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 2I:2:7
Port: 2I
Box: 2
Bay: 7
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD6
Serial Number: EB01PD21MVF51306
Model: HP EG0300FBDSP
Current Temperature (C): 31
Maximum Temperature (C): 44
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380
Device Number: 380
Firmware Version: RevB
WWID: 50014380263D1E4F
Vendor ID: PMCSIERA
Model: SRCv8x6G
上图所示,服务器做了两个RAID,分别是Array A 和 Array B,前者由两块硬盘组建了RAID 1,后者由四块硬盘组建了RAID 0。
文章浏览阅读2w次,点赞7次,收藏51次。四个步骤1.创建C++ Win32项目动态库dll 2.在Win32项目动态库中添加 外部依赖项 lib头文件和lib库3.导出C接口4.c#调用c++动态库开始你的表演...①创建一个空白的解决方案,在解决方案中添加 Visual C++ , Win32 项目空白解决方案的创建:添加Visual C++ , Win32 项目这......_c#调用lib
文章浏览阅读4.6k次。苹方字体是苹果系统上的黑体,挺好看的。注重颜值的网站都会使用,例如知乎:font-family: -apple-system, BlinkMacSystemFont, Helvetica Neue, PingFang SC, Microsoft YaHei, Source Han Sans SC, Noto Sans CJK SC, W..._ubuntu pingfang
文章浏览阅读159次。表单表单概述表单标签表单域按钮控件demo表单标签表单标签基本语法结构<form action="处理数据程序的url地址“ method=”get|post“ name="表单名称”></form><!--action,当提交表单时,向何处发送表单中的数据,地址可以是相对地址也可以是绝对地址--><!--method将表单中的数据传送给服务器处理,get方式直接显示在url地址中,数据可以被缓存,且长度有限制;而post方式数据隐藏传输,_html表单的处理程序有那些
文章浏览阅读1.2k次。使用说明:开启Google的登陆二步验证(即Google Authenticator服务)后用户登陆时需要输入额外由手机客户端生成的一次性密码。实现Google Authenticator功能需要服务器端和客户端的支持。服务器端负责密钥的生成、验证一次性密码是否正确。客户端记录密钥后生成一次性密码。下载谷歌验证类库文件放到项目合适位置(我这边放在项目Vender下面)https://github.com/PHPGangsta/GoogleAuthenticatorPHP代码示例://引入谷_php otp 验证器
文章浏览阅读4.3k次,点赞5次,收藏11次。matplotlib.plot画图横坐标混乱及间隔处理_matplotlib更改横轴间距
文章浏览阅读2.2k次。①Storage driver 处理各镜像层及容器层的处理细节,实现了多层数据的堆叠,为用户 提供了多层数据合并后的统一视图②所有 Storage driver 都使用可堆叠图像层和写时复制(CoW)策略③docker info 命令可查看当系统上的 storage driver主要用于测试目的,不建议用于生成环境。_docker 保存容器
文章浏览阅读834次,点赞27次,收藏13次。网络拓扑结构是指计算机网络中各组件(如计算机、服务器、打印机、路由器、交换机等设备)及其连接线路在物理布局或逻辑构型上的排列形式。这种布局不仅描述了设备间的实际物理连接方式,也决定了数据在网络中流动的路径和方式。不同的网络拓扑结构影响着网络的性能、可靠性、可扩展性及管理维护的难易程度。_网络拓扑csdn
文章浏览阅读1.8k次,点赞5次,收藏8次。IOS系统Date的坑要创建一个指定时间的new Date对象时,通常的做法是:new Date("2020-09-21 11:11:00")这行代码在 PC 端和安卓端都是正常的,而在 iOS 端则会提示 Invalid Date 无效日期。在IOS年月日中间的横岗许换成斜杠,也就是new Date("2020/09/21 11:11:00")通常为了兼容IOS的这个坑,需要做一些额外的特殊处理,笔者在开发的时候经常会忘了兼容IOS系统。所以就想试着重写Date函数,一劳永逸,避免每次ne_date.prototype 将所有 ios
文章浏览阅读5.3k次。方法一:用PLSQL Developer工具。 1 在PLSQL Developer的sql window里输入select * from test for update; 2 按F8执行 3 打开锁, 再按一下加号. 鼠标点到第一列的列头,使全列成选中状态,然后粘贴,最后commit提交即可。(前提..._excel导入pl/sql
文章浏览阅读83次。Git常用命令速查手册1、初始化仓库git init2、将文件添加到仓库git add 文件名 # 将工作区的某个文件添加到暂存区 git add -u # 添加所有被tracked文件中被修改或删除的文件信息到暂存区,不处理untracked的文件git add -A # 添加所有被tracked文件中被修改或删除的文件信息到暂存区,包括untracked的文件...
文章浏览阅读202次。分享119个ASP.NET源码总有一个是你想要的_千博二手车源码v2023 build 1120
文章浏览阅读1.8k次。版权声明:转载请注明出处 http://blog.csdn.net/irean_lau。目录(?)[+]1、缺省构造函数。2、缺省拷贝构造函数。3、 缺省析构函数。4、缺省赋值运算符。5、缺省取址运算符。6、 缺省取址运算符 const。[cpp] view plain copy_空类默认产生哪些类成员函数